From Concept to Wearable Prototype

Embedded Systems & Product Development

This independent development project began with a practical idea: to design and build a compact wearable device with complete control over every aspect of the system, from the electronics and firmware to the Android application and mechanical enclosure.

The original motivation came from my experience with electromagnetic compatibility (EMC) testing.

At the EMC laboratory, there were situations where having the basic functionality of a smartwatch would be useful, but an active Bluetooth transmitter could introduce unwanted interference. During some EMC tests, non-essential wireless devices had to be kept outside the test environment to avoid unintended emissions influencing the equipment under test (EUT) and potentially affecting the test results.

I wanted to explore a different approach: a smartwatch where Bluetooth could be deliberately disabled at the hardware or firmware level when required, rather than simply disconnected from a paired phone.

What started as a relatively simple requirement gradually evolved into a much more ambitious engineering challenge: designing, developing and building a working smartwatch prototype from the ground up.


The Engineering Need

The objective was never to compete with commercial smartwatches or reproduce their extensive range of features.

Instead, I wanted to develop a compact embedded platform that provided essential wearable functionality while maintaining full control over the electronics, firmware and wireless communications.

Rather than relying on an off-the-shelf development board or an existing smartwatch platform, I chose to design the electronics around the specific requirements of the project.

The key functions included a colour graphical interface, accurate local timekeeping, motion sensing, Bluetooth communication with an Android smartphone, battery-powered operation and the ability to disable wireless communications when necessary.

Equally important was turning the electronics into a practical, self-contained device. This meant addressing not only circuit design and embedded software, but also PCB layout, power management, component integration, mechanical packaging and the development of a suitable enclosure.

The aim was to take the project beyond a working electronics prototype and demonstrate how the different engineering disciplines could come together in a complete, wearable system.

Defining the Architecture

The first stage was selecting an architecture that was flexible enough for experimentation but simple enough to develop independently.

The design was based around a PIC microcontroller and a 1.44-inch colour TFT with a resistive touchscreen.

Different peripheral interfaces were required around it.

SPI was used for the display, I²C for devices such as the real-time clock and accelerometer, and UART for the Bluetooth interface.

A DS3231 provided real-time clock functionality, an MPU-6050 provided motion sensing, and an HC-06 module provided the first Bluetooth implementation.

Some ideas were investigated and deliberately left out of Version 1, including GPS and an early heart-rate sensing solution.

That process was useful in itself. Product development is not only about deciding what to add; it is also about deciding which features are not yet worth the additional hardware, software, power consumption or mechanical complexity.

Early architecture and component evaluation, including parts considered and rejected during development

Prototyping the Complete System

Before designing a PCB, the main functions were built and tested using development hardware.

At this stage the objective was not appearance.

It was to answer basic engineering questions.

Could the display and touchscreen be driven reliably?

Could the RTC and accelerometer share the required interfaces?

Could the microcontroller communicate reliably with the Bluetooth module?

Could the different parts operate together rather than only as isolated demonstrations?

The early prototype was messy, but it allowed those questions to be answered before committing the design to a PCB.

Early functional prototype used to validate the display, touchscreen, sensors and Bluetooth communication before PCB design

Firmware and Android Integration

A wearable is only useful if the embedded hardware can interact with the system around it.

For this project I developed the embedded firmware, the Android side of the communications and a simple Windows app for testing purposes.

The Android application could connect to and disconnect from the watch, synchronise its real-time clock and forward notifications from applications such as messaging, email and calendar services.

Communication also worked in the other direction.

Touch controls on the watch could send commands back to the Android device, including changing the phone volume.

A simple communications protocol was therefore developed between the embedded firmware and the application rather than treating Bluetooth as just a transparent serial link.

This became one of the most interesting parts of the project because the electronics, firmware and application software all had to agree on the same system behaviour.

Custom Android application used for Bluetooth connection, clock synchronisation and bidirectional control

From Breadboard to a Custom PCB

Once the main functions had been proven, the design moved to a custom PCB.

This changed the nature of the project considerably.

A breadboard allows many decisions to remain temporary. A PCB forces those decisions to become physical.

Power distribution, battery protection, programming access, component placement, test points, connectors and signal routing all had to be considered together.

The schematic was organised around the main functional areas: power, microcontroller and peripherals, and the user interface.

The resulting PCB integrated the microcontroller, RTC, accelerometer, Bluetooth interface, battery circuitry, ICSP programming connection and display interface into a single assembly.

This was the point where the project moved from an electronics experiment towards an actual product prototype.

Custom electronics integrating power management, microcontroller, sensing, Bluetooth and the user interface

Progression from PCB design and assembly to the first functioning wearable hardware

Mechanical Design and Packaging

A working PCB still wasn’t a wearable product.

The electronics needed an enclosure that could hold the display, PCB and battery while allowing the device to be worn normally.

I designed a custom enclosure around the electronics and produced a physical prototype.

The first version worked, but it also exposed one of the clearest limitations of the design: it was simply too large.

That was a useful lesson.

For compact embedded products, mechanical design cannot really be left until the electronics are finished. Component selection, PCB dimensions, connector placement, battery choice and enclosure geometry all influence each other.

A second version would therefore need the electronics and enclosure to evolve together rather than sequentially.

Custom enclosure developed around the display, PCB and battery

Testing the First Prototype

The completed prototype was then used as a real system rather than simply checked for basic power-up.

Phone notifications could be received.

The clock could be synchronised from the Android application.

Commands could be sent from the touchscreen back to the phone.

Accelerometer data could be acquired and communicated.

Battery-life testing also demonstrated how strongly communications architecture affects a wearable product.

With Bluetooth continuously connected, the prototype operated for approximately 1.5 days.

With Bluetooth enabled but disconnected, this increased to roughly 2.5 days.

With Bluetooth switched off, operation increased to approximately 5–7 days.

That result made the direction for a future design very clear.

Functional testing of the assembled prototype and user interface

What Didn’t Work Perfectly

Not everything worked as intended, and those results were just as useful as the successful ones.

The enclosure was larger than desirable.

Battery-state estimation was not accurate enough.

Some low-power operating behaviour required further development.

The RTC idle-mode implementation was not behaving as intended, and the microcontroller sleep strategy did not work correctly with Bluetooth serial wake-up.

These were not reasons to hide the prototype.

They were the information needed to define Version 2.

What V1 Taught Me

The project highlighted how quickly a seemingly simple embedded idea becomes a multidisciplinary product-development exercise.

The obvious next step for wireless communication was to move from Bluetooth Classic towards BLE to reduce power consumption and PCB space.

Battery monitoring needed refinement.

A lower-power accelerometer could reduce consumption while adding useful functionality such as hardware step counting.

The PCB and enclosure both needed another iteration to make the product smaller and more ergonomic.

Most importantly, the project demonstrated the value of developing the complete system rather than optimising one subsystem in isolation.

Electronics architecture affects firmware.

Firmware affects power consumption.

Wireless communication affects battery life.

PCB dimensions affect mechanical design.

Mechanical design feeds back into component selection.

That interaction is where much of the real engineering happens.

Outcome

The project progressed from a simple idea to a working custom wearable incorporating embedded electronics, firmware, touchscreen user interface, Bluetooth communication, Android integration, motion sensing, battery operation, a custom PCB and a purpose-designed enclosure.

It was not intended to compete with a commercial smartwatch.

Its value was in developing every part of the product and understanding how those parts interacted in real hardware.

The original EMC-related requirement — retaining useful wearable functionality while having direct control over when the Bluetooth function was active — ultimately became the starting point for a much broader embedded-product development project.

And perhaps the most useful result was not the watch itself.

It was seeing the complete path from concept → architecture → prototype → PCB → software → mechanical design → testing → next iteration.


Need support developing an embedded product?

ElectronPath supports embedded-system architecture, electronics and PCB design/review, firmware troubleshooting, hardware validation and practical product-development support from early concept through prototype.

Discuss Your Project →